Colorlight SSR Series Transducer

$60.00$300.00

Colorlight SSR series transducer is a high performance led display sensor, main model including: SSRL29/SSRL16/SSR-TEMP/SSR-NOISE/SSR-SMOG/SSR-PM.

Free worldwide shipping on all orders over $500

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

Colorlight SSR Series Transducer

Colorlight SSR series transducer is a high performance led display sensor, main model including: SSRL29/SSRL16/SSR-TEMP/SSR-NOISE/SSR-SMOG/SSR-PM. It uses advanced sensing technology to accurately detect parameters such as ambient brightness and temperature, and adjust the brightness and color of the LED display in real time to achieve the best results. SSR series sensors can provide accurate environmental monitoring and automatic adjustment functions, so that the LED display can maintain excellent display effects in different environments.

1. Colorlight Ambient Brightness Sensor

Monitor environmental brightness, and auto adjust the brightness of LED display according to environmental brightness value and brightness adjustment strategy set up before, to achieve the aim of environmental protection and ensuring best viewing effect(photo eye control system).

SSRL29

1). Connect with iM9 multifunction card with 4 optional extended interfaces;
2). Standard wire length: 5 meter, can be lengthened;
3). For outdoor use, three proofing properties included;
4). Do not require an external power supply;
5). Appearance size: Ǿ45*50.

SSRL16

1). Connect with iM9 multifunction card with 4 optional extended interfaces;
2). Standard wire length: 5 meter, can be lengthened;
3). For outdoor use, three proofing properties included;
4). Do not require an external power supply;
5). Appearance size: Ǿ32*41.

2. Colorlight Temperature and Humidity Sensor

SSR-TEMP is a high-precision temperature and humidity sensor with good-looking and small appearance, it is designed with standard guide rail structure and it has easy wire connection and simple installation. It adopts imported high-precision probe and ensures excellent measurement performance; has high stability and anti-interference ability, also has strong barrier property with first-class lightning protection. Multiple modules can be connected to the bus network via RS485 interface to monitor multiple environmental conditions in real time.

1). RS485 interface, communication distance up to 1200 meter;
2). Imported probe, high precision, wide range, good consistency;
3). Designed with standard guide rail structure, easy installation;
4). High stability and anti-interference ability;
5). Input voltage: DC5~12V;
6). MODBUS RTU standard communication protocol;
7). Strong barrier property, first-class lightning protection.

Rated voltageDC5V-12V
Measuring rangeTemperature:-40℃~120℃                 Humidity:0~100%rh
Measuring accuracyTemperature: ±0.3℃ Resolution: 0.1℃                 Humidity:±3%rh Resolution: 0.1rh
Output interfaceRS485
Communication protocolMODBUS RTU
Communication address1-247
Baud rate1200 bit/s,2400 bit/s, 4800 bit/s, 9600 bit/s, 19200 bit/s
Average power consumption<0.1W
Wire length5 meter (standard)
InstallationGuide rail mounting, walls mounting indoors, ceilings mounting

3. Colorlight SSR-NOISE Sensor

Adopt direct-reading decibel noise level detection module developed by the original imported sound sensor; Multi-points calibration craft with high detection accuracy and sensitivity; Unique stainless steel probe packaged separately, available for embedding other equipment; Core components of circuits of the main board are totally shielded for beauty and strong anti-interference capability; Various output types (TTL/I2C, 485 interface of standard Modbus Rtu protocol) are reserved for all kinds of application integrations; Standard wire length: 5 meter.

1). Adopt direct-reading decibel noise level detection module developed by the original imported sound sensor;
2). Multi-points calibration craft with high detection accuracy and sensitivity;
3). Unique stainless steel probe packaged separately, available for embedding other equipment;
4). Core components of circuits of the main board are totally shielded for beauty and strong anti-interference capability;
5). Various output types (TTL/I2C, 485 interface of standard Modbus Rtu protocol) are reserved for all kinds of application integrations;
6). Standard wire length: 5 meter.

Specification:

4. Colorlight SSR-SMOG Transducer

SSR-SMOG smoke transducer with ceiling type adopts highly sensitive smoke sensor imported from Korea as core detection device, it can make qualitative measurement of various smokes with high precision of 2000PPM; SSR-SMOG has characteristics like wide measuring range, built-in alarm function, good linearity, easy to use, simple installation, far transmission distance, etc., which is suitable for all kinds of places.

Probe is available for measurement of lampblack, smog, etc. SSR-SMOG is commonly used to qualitative measurement. SSR-SMOG has special design and it is convenient to replace the probe. The module adopts MODBUS-RTU communication protocol which is widely used in industry and supports secondary development. Users can achieve queries and settings of module’s data with arbitrary serial communication software according to the communication protocol.

1). RS485 telecommunication, can be controlled remotely;
2). Low power consumption, high-decibel alarm;
3). Sound-light alarm, long service life;
4). Ceiling mounting, easy and convenient;
5). Standard wire length: 5 meter.

Specification:

5. Colorlight SSR-PM Air quality (PM2.5/PM10) Transmitter

SSR-PM is an industrial transmitter universal particle concentration, measured using laser light scattering principle, the unique data acquisition technology dual sieved particles obtained number of particles per unit volume equivalent particle diameter, and a unique scientific the algorithm calculates the concentration of particulate matter per unit volume equivalent particle diameter, and is output via data interface 485 ModBus-RTU protocol. It can be used for monitoring the concentration of PM10 or PM2.5 need a place outdoor weather, dust monitoring, libraries, archives, and other industrial plants.

1). Range: 0-6000ug/m3, the resolution: 1ug/m3;
2). PM2.5, PM10 simultaneous output;
3). Unique dual automatic data acquisition and calibration techniques, consistency of up to ±10%;
4). The use of advanced laser anti-attenuation technology to ensure long-term stability of equipment;
5). ModBus-RTU standard communication protocol, easy access;
6). Standard wire length: 5 meter.

Specification:

Additional information

Weight 0.15 kg
Dimensions 15 × 10 × 1 cm
Model: No selection

SSRL29, SSRL16, SSR-TEMP, SSR-NOISE, SSR-SMOG, SSR-PM

Reviews

There are no reviews yet.

Be the first to review “Colorlight SSR Series Transducer”

Your email address will not be published. Required fields are marked *